Issue 48
All That Glisters is Not Au/Ag/Pt/Pd/Ru/Rh/Ir/Et Al
The precious metals trade is diverse, and this is no less true when we look into the analysis of the metals and minerals involved. The chemistry of precious metals can be both complex and intriguing, and often chemists will build an enviable knowledge and understanding after years of working in laboratories.
Over recent years, higher metal prices, efficient lines of communication and the advance of technology into laboratories has had a positive effect on the analyst, and there has been a need for laboratories’ performance to keep up to pace. Quality and reliability of assay results are the most important factors due to the fact that exchange splitting limits* on all metals – and especially precious metals – have tightened, necessitating that assay results be precise and accurate. Any delay can be costly to all parties involved. The analysis of precious metals covers a wide spectrum, from poor-grade materials containing only parts per million (ppm) to metals of 99.999% purity. Our laboratory reflects this: the diverse range of precious-metal-bearing materials that we assay includes sweeps, jewellery scrap, resins, catalysts, bullion, doré, electronic scrap, solutions, conductor pastes, concentrates and residues, in addition to the occasional non-standard specialized alloys/products.
Assaying of such materials involves different analytical techniques according to the particular criteria of each sample, including the base carrier (the substrate of the material) and precious metal contained.
To establish the composition of the sample, it is often necessary to carry out a preliminary fact-finding assay or trial. Once the matrix of the material is known, the chemist can make a judgment and choose the most appropriate assaying method to be applied. This approach is essential, and highly skilled chemists complement any decision within a modern laboratory equipped with reliable instrumentation.
This preliminary assay is especially significant in the assaying of the platinum group metals (pgms), as the ratio of the precious metals contained in the sample will dictate the analytical procedure.
Even the most modern and up-to-date techniques are dependent on the representative sample for analysis being true and homogeneous. The extreme importance attached to obtaining a sample that accurately represents the total original material cannot be stressed too strongly – errors made during the sampling process cannot be corrected in the course of analysis. The sample must be in a state that will support the expected accuracy and precision of the method and instrumentation.
In addition to the preliminary fact-finding assays previously mentioned, preparation of the material or sample may be required prior to commencing the actual analysis. Some samples received in the laboratory will have already been prepared and be in a suitable condition for analysis, the first stage invariably being moisture determination.
However, laboratories will also receive materials in various shapes and in conditions ranging from natural state to partially prepared – for example electronic scrap, ores, catalysts and production residues that will require extensive sample preparation. This may involve melting, matting, milling, screening, leaching and drying before the sample is suitably prepared and ready for assaying.
Techniques used for precious metal analysis may include:
- Fire Assay
- Inductively Coupled Plasma Optical Emission and Mass Spectrometry (ICP OES and ICP MS)
- X-Ray Fluorescence Spectrometry (XRF)
- Gravimetric Analysis
- Microwave Digestion.
A description of some of these principles and techniques follows.
*Exchange splitting limits: Splitting limits are specified in the contract between the seller of the material and the buyer. If the difference between the assay obtained by the buyer and that obtained by the seller is within the specified limit, the two parties agree to split the difference. If the difference is outside those parameters, the matter then goes to umpire – an independent assayer – which is also named in the contract.
Fire Assay
Fire assaying, a technique that has been used throughout the world for centuries – it is recorded as long ago as the ancient Egyptians – is still the most generally accepted method of analysis for gold and platinum group elements. It has stood the test of time due to some distinct advantages, notably large sample weights and separation of the precious metal from the base carrier, which reduces interference.
Fire assaying is used for the determination of gold, silver and pgms in all types of materials, ranging from bullion, jewellery and ores to concentrates and electronic scrap. The methods have been modernised, and aligning this technique alongside the latest instrumentation can provide the most accurate results.
In principle the weighed sample is fused at a temperature in excess of 1000 degrees Celsius in a flux made up of various constituents, the purpose of which is to reduce the metal oxide constituent (usually lead, but it could also be nickel, copper or tin from its oxide to the metal).
In the smelting, a slag phase is also created, which will aid the removal of base metals and gangue materials (sand, rock and other impurities) from the metal button, which then collects the precious metal and sinks to the bottom of the crucible. When fusion is complete, the crucible contents are poured into a cast-iron mould and the button containing the precious metals and the slag are separated. The slag is washed again with additional flux to ensure complete collection of the precious metal, and is discarded.
Depending on the metal oxide used as the collector in the flux, different chemical processes take place.
If lead is used, the next stage is to remove the lead, through a technique known as cupellation, wherein the button is placed on a cupel (a porous pot made from magnesium oxide) in a muffle furnace with good airflow at a temperature of approximately 950 degrees Celsius. The cupel has an affinity for lead oxide, and acts as a filter, absorbing the lead oxide as it forms from the molten lead. This process leaves the precious metal bead on the cupel, which can be weighed accurately to obtain total precious metal weight. This bead is then treated further using nitric acid to determine the metals in the bead, usually silver, gold (gravimetrically), platinum and palladium (ICP).
In the assay of doré, the bullion samples are weighed and placed directly into lead foil and cupellated (they do not have to undergo fusion as they are already free from significant base metals). The beads can be weighed using accurate balances capable of weighing to seven decimal places. Parting in nitric acid separates the silver and gold from each other – the silver is dissolved and the gold remains as the metal, which is dried and annealed and weighed to calculate the percentage in the sample. Various corrections are necessary, made using standards of pure metal alongside the assays.
The noble metals are analysed more frequently by nickel collection. This technique uses nickel oxide as the collector, and it is possible to determine a range of metals in one procedure, namely platinum, palladium, rhodium, iridium and ruthenium. This method does not use cupellation to separate the collected precious metals, but instead dissolves the pulverised nickel button in acid. The nickel is removed by filtration, the remaining residue of precious metals is treated and the final determination of the solutions is made using instrumentation such as ICP.
ICP OES: Inductively Coupled Plasma Optical Emission Spectrometry
ICP spectrometry analyses solutions of samples of known weights into known volumes by the most appropriate preparation method for the type of sample. The resulting solution from direct dissolution of the sample or from parting of the precious metal beads from fire assay is then analysed directly on an ICP spectrometer. This method requires comparative standards and reference samples and has the advantage that it can measure a range of elements simultaneously.
ICP spectrometry is an excellent method for measuring pgms in solution. It is an emission technique, which requires the sample to pass through a nebuliser to create a fine mist. This is then swept into the plasma via a spray chamber and a torch. The plasma itself is a high-energy source that causes the atoms and ions within the sample to absorb energy and reach higher energy states. They then revert to their normal energy states in the cooler part of the plasma, thus giving off energy in the form of light, which is then measured by the spectrometer.
The great benefit of ICP is that linear calibrations can be obtained over orders of magnitude not possible by other comparable techniques. This, coupled with the fact that modern spectrometers use CCD (charge coupled device) detectors to measure light over the whole spectrum range, means that fast multiple-element-wavelength determinations can be made from just one solution containing ppm levels up to higher concentrations.
ICP as a technique does have a number of interferences, which the analyst needs to be aware of. Matrix interferences can be overcome by making sure that the samples and standards have the same acid strength and alloy base.
An internal standard should also be added to the solutions – pgm elements have both atomic and ionic wavelengths, which can behave differently in the plasma, so an internal standard should match these characteristics.
Matrix effects can also affect the background of a spectrum, therefore suitable background correction should also be applied to each elemental wavelength being measured. Inter-element interferences can be problematic and need to be overcome (they are reduced using correction factors).
Pgm samples are run with calibration check standards, reference materials and drift- correction software to ensure the high quality of the analysis reported from the ICP instruments.